Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Front Public Health ; 11: 1144420, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2295946

RESUMEN

Background: Previous studies have confirmed that both affect and emotion regulation strategies are closely associated with psychological capital (PsyCap) and resilience. These factors are assumed to buffer the effect of the COVID-19 pandemic on mental health, especially among males. However, these interactions have not been closely examined to date. To fill this gap, this paper explores the dimension-level relationships of these psychological constructs among Chinese males during the late stage of the COVID-19 pandemic and identified critical bridge dimensions using network analysis. Methods: A total of 1,490 Chinese males aged 21-51 years completed self-report scales assessing emotion regulation strategies, affect, PsyCap, and psychological resilience. Two regularized partial correlation networks, namely the affect and emotion regulation-PsyCap network and the affect and emotion regulation-psychological resilience network, were then constructed to examine links between the dimensions of these constructs. The bridge expected influence (BEI) index was also calculated for each node to identify important bridge nodes. Results: Positive affect, negative affect, cognitive reappraisal, and expressive suppression showed distinct and complex links to various dimensions of PsyCap or psychological resilience. In both networks, positive affect, cognitive reappraisal, and negative affect were identified as critical bridge nodes, with the first two having positive BEI values and the third having a negative value. Conclusion: The findings elucidate the specific role of the dimensions of emotion regulation or affect in relation to PsyCap and psychological resilience, which facilitates further understanding of the mechanisms underlying these interrelationships. These findings also provide implications for developing effective intervention strategies to increase PsyCap and psychological resilience.


Asunto(s)
Afecto , COVID-19 , Pueblos del Este de Asia , Regulación Emocional , Hombres , Pandemias , Resiliencia Psicológica , Humanos , Masculino , COVID-19/epidemiología , COVID-19/psicología , Pueblos del Este de Asia/psicología , Metaanálisis en Red , Hombres/psicología , Adulto Joven/psicología , Adulto/psicología , Persona de Mediana Edad/psicología , Adaptación Psicológica
2.
Frontiers in immunology ; 14, 2023.
Artículo en Inglés | EuropePMC | ID: covidwho-2269451

RESUMEN

Platelet factor 4 (PF4), also known as chemokine (C-X-C motif) ligand 4 (CXCL4), is a specific protein synthesized from platelet α particles. The combination of PF4 and heparin to form antigenic complexes is an important mechanism in the pathogenesis of heparin-induced thrombocytopenia (HIT), but vaccine-induced immune thrombotic thrombocytopenia (VITT) related to the COVID-19 vaccine makes PF4 a research hotspot again. Similar to HIT, vaccines, bacteria, and other non-heparin exposure, PF4 can interact with negatively charged polyanions to form immune complexes and participate in thrombosis. These anions include cell surface mucopolysaccharides, platelet polyphosphates, DNA from endothelial cells, or von Willebrand factor (VWF). Among them, PF4–VWF, as a new immune complex, may induce and promote the formation of immune-associated thrombosis and is expected to become a new target and therapeutic direction. For both HIT and VITT, there is no effective and targeted treatment except discontinuation of suspected drugs. The research and development of targeted drugs based on the mechanism of action have become an unmet clinical need. Here, this study systematically reviewed the characteristics and pathophysiological mechanisms of PF4 and VWF, elaborated the potential mechanism of action of PF4–VWF complex in immune-associated thrombosis, summarized the current status of new drug research and development for PF4 and VWF, and discussed the possibility of this complex as a potential biomarker for early immune-associated thrombosis events. Moreover, the key points of basic research and clinical evaluation are put forward in the study.

3.
Front Psychol ; 14: 1057460, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2255892

RESUMEN

Background: Nurses' work alienation has become increasingly serious due to the increase in workload and risk during the coronavirus disease 2019 (COVID-19). However, no studies have investigated the link between empathy, ego depletion, and work alienation among Chinese nurses. The present study aimed to evaluate Chinese nurses' empathy, ego depletion, and work alienation and to examine whether nurses' ego depletion mediates the relationship between empathy and work alienation. Methods: This was a descriptive, cross-sectional study involving 353 nurses from Shaanxi. The Jefferson Scale of Empathy-Health Professionals, Self-Regulating Fatigue Scale and Work Alienation Questionnaire were used to collect data through an online survey. Structural equation modeling was conducted to analyze the mediating model. Results: Work alienation was negatively correlated with empathy (r = -0.305, p < 0.01) and positively correlated with ego depletion (r = 0.652, p < 0.01). Empathy was negatively correlated with ego depletion (r = -0.325, p < 0.01). Empathy can directly predict work alienation (ß = -0.263, p < 0.01), while ego depletion has a mediating effect between empathy and work alienation (ß = -0.309, p < 0.01), and the mediating effect accounts for 54.02% of the total effect. Conclusion: Nurses' work alienation was at a moderate-to-high level. Improving empathy can reduce work alienation through less ego depletion. Nursing managers should discover nurses' work alienation as soon as possible. Interventions to improve empathy can help replenish nurses' psychological resources, thereby reducing ego depletion and work alienation.

4.
Front Immunol ; 14: 1098665, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2269468

RESUMEN

Platelet factor 4 (PF4), also known as chemokine (C-X-C motif) ligand 4 (CXCL4), is a specific protein synthesized from platelet α particles. The combination of PF4 and heparin to form antigenic complexes is an important mechanism in the pathogenesis of heparin-induced thrombocytopenia (HIT), but vaccine-induced immune thrombotic thrombocytopenia (VITT) related to the COVID-19 vaccine makes PF4 a research hotspot again. Similar to HIT, vaccines, bacteria, and other non-heparin exposure, PF4 can interact with negatively charged polyanions to form immune complexes and participate in thrombosis. These anions include cell surface mucopolysaccharides, platelet polyphosphates, DNA from endothelial cells, or von Willebrand factor (VWF). Among them, PF4-VWF, as a new immune complex, may induce and promote the formation of immune-associated thrombosis and is expected to become a new target and therapeutic direction. For both HIT and VITT, there is no effective and targeted treatment except discontinuation of suspected drugs. The research and development of targeted drugs based on the mechanism of action have become an unmet clinical need. Here, this study systematically reviewed the characteristics and pathophysiological mechanisms of PF4 and VWF, elaborated the potential mechanism of action of PF4-VWF complex in immune-associated thrombosis, summarized the current status of new drug research and development for PF4 and VWF, and discussed the possibility of this complex as a potential biomarker for early immune-associated thrombosis events. Moreover, the key points of basic research and clinical evaluation are put forward in the study.


Asunto(s)
COVID-19 , Púrpura Trombocitopénica Idiopática , Trombocitopenia , Trombosis , Humanos , Aceleración , Complejo Antígeno-Anticuerpo , COVID-19/complicaciones , Vacunas contra la COVID-19/efectos adversos , Células Endoteliales/metabolismo , Heparina/metabolismo , Factores Inmunológicos , Factor Plaquetario 4 , Púrpura Trombocitopénica Idiopática/complicaciones , Trombocitopenia/etiología , Trombosis/complicaciones , Factor de von Willebrand
5.
Front Public Health ; 10: 1073409, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-2229166

RESUMEN

Background: Family function plays a pivotal role in self-management among patients with early chronic kidney disease (CKD), which has been especially important during the COVID-19 pandemic. Previous studies have investigated the relationships between family function and self-management using total scores through self-report questionnaires while ignoring the different components in both family function and self-management. The specific objective of this study was to explore the network structure of family function and self-management at the component level. Methods: A total of 360 patients with early CKD from three tertiary hospitals were enrolled in our cross-sectional survey from September to December 2021 in China. Components of family function were measured by the Family Adaptation Partnership Growth and Resolve Index, and components of self-management were measured by the Chronic Kidney Disease Self-management Instrument. Network analysis was used to establish the network structure. Results: Edges across the community of family function and self-management were mainly positive. Edges between F3 "Growth" and M1 "Self-integration", F2 "Partnership" and M3 "Seeking social support," F5 "Resolve" and M3 "Seeking social support" were the strongest. F3 "Growth" had the greatest positive bridge expected influence of family function community (0.12), and M3 "Seeking social support" had the greatest positive bridge expected influence of self-management community (0.16). Conclusion: We explored the potential pathways between different components of family function and self-management among patients with early CKD during the COVID-19 pandemic and found fine-grained relationships between them. The two nodes F3 "Growth" and M3 "Seeking social support" may provide a new idea from the perspective of family function for interventions to improve self-management.


Asunto(s)
COVID-19 , Insuficiencia Renal Crónica , Automanejo , Humanos , Estudios Transversales , Pandemias , Insuficiencia Renal Crónica/terapia , Insuficiencia Renal Crónica/epidemiología
6.
Frontiers in public health ; 10, 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-2207504

RESUMEN

Background Family function plays a pivotal role in self-management among patients with early chronic kidney disease (CKD), which has been especially important during the COVID-19 pandemic. Previous studies have investigated the relationships between family function and self-management using total scores through self-report questionnaires while ignoring the different components in both family function and self-management. The specific objective of this study was to explore the network structure of family function and self-management at the component level. Methods A total of 360 patients with early CKD from three tertiary hospitals were enrolled in our cross-sectional survey from September to December 2021 in China. Components of family function were measured by the Family Adaptation Partnership Growth and Resolve Index, and components of self-management were measured by the Chronic Kidney Disease Self-management Instrument. Network analysis was used to establish the network structure. Results Edges across the community of family function and self-management were mainly positive. Edges between F3 "Growth” and M1 "Self-integration”, F2 "Partnership” and M3 "Seeking social support,” F5 "Resolve” and M3 "Seeking social support” were the strongest. F3 "Growth” had the greatest positive bridge expected influence of family function community (0.12), and M3 "Seeking social support” had the greatest positive bridge expected influence of self-management community (0.16). Conclusion We explored the potential pathways between different components of family function and self-management among patients with early CKD during the COVID-19 pandemic and found fine-grained relationships between them. The two nodes F3 "Growth” and M3 "Seeking social support” may provide a new idea from the perspective of family function for interventions to improve self-management.

7.
Frontiers in psychiatry ; 13, 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-2072945

RESUMEN

Background Self-management in patients with early chronic kidney disease (CKD) can effectively delay damage to renal function. However, with the continuous spread of COVID-19, patients cannot receive timely treatment, which can lead to different affects, resulting in ego depletion and serious challenges to self-management. This study aimed to investigate the mediating and suppressing roles of ego depletion on the relationship between positive and negative affect and self-management among patients with early CKD during the COVID-19 pandemic in China. Methods A total of 383 patients with early CKD from three tertiary hospitals were enrolled by convenience sampling in our cross-sectional study from September 2021 to March 2022. Participants completed the Sociodemographic Questionnaire, Positive Affect and Negative Affect Scale, Self-Regulating Fatigue Scale and Chronic Kidney Disease Self-Management Instrument. A structural equation model was conducted to test the mediating and suppressing effects of ego depletion on the relationship between positive and negative affect and self-management. Results The average score of the participants' self-management was 84.54 (SD: 19.72), and nearly 60% of them were at low and moderate levels. The mediating effect of positive affect on self-management through ego depletion was significant (β = 0.248, 95% CI: 0.170 to 0.376), accounting for 53.22% of the total effect. The suppressing effect of negative affect on self-management through ego depletion was significant (β = −0.191, 95% CI: −0.310 to −0.118), and the absolute value of the ratio of the suppressing effect to the direct effect was 66.55%. Conclusions Ego depletion partially mediated the relationship between positive affect and self-management while suppressing the relationship between negative affect and self-management among patients with early CKD during the COVID-19 pandemic. The reduction of patients' ego depletion must be taken as the intervention target to improve self-management and delay the progression of CKD.

8.
Am J Infect Control ; 50(8): 857-862, 2022 08.
Artículo en Inglés | MEDLINE | ID: covidwho-2000224

RESUMEN

BACKGROUND: Global shortage of personal protective equipment (PPE), as consequence of the COVID-19 global pandemic, has unmasked significant resource inequities prompting efforts to develop methods for safe PPE decontamination for reuse. The World Health Organization (WHO) in their Rational Use of PPE bulletin cited the use of a photodynamic dye, methylene blue, and light exposure as a viable option for N95 respirator decontamination. Because WHO noted that methylene blue (MB) would be applied to surfaces through which health care workers breathe, we hypothesized that little to no MB will be detectable by spectroscopy when the PPE is subjected to MB at supraphysiologic airflow rates. METHODS: A panel of N95 respirators, medical masks, and cloth masks were sprayed with 5 cycles of 1,000 uM MB solution. Mask coupons were subjected to the equivalent of 120 L/min of 100% humidified air flow. Effluent gas was trapped in an aqueous solution and the resultant fluid was sampled for MB absorbance with a level of detection of 0.004 mg/m3. RESULTS: No detectable MB was identified for any mask using Ultraviolet-Visible spectroscopy. CONCLUSIONS: At 500-fold the amount of MB applied to N95 respirators and medical masks as were used for the decontamination study cited in the WHO Rational Use of PPE bulletin, no detectable MB was observed, thus providing safety evidence for the use of methylene blue and light exposure for mask decontamination.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/prevención & control , Descontaminación/métodos , Equipo Reutilizado , Humanos , Azul de Metileno , Respiradores N95
9.
Gastroenterology ; 163(1): 336-337, 2022 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1830208
10.
Front Biosci (Landmark Ed) ; 27(2): 48, 2022 02 11.
Artículo en Inglés | MEDLINE | ID: covidwho-1772157

RESUMEN

BACKGROUND: Thymosin-α1 has been implicated into the treatment of novel respiratory virus Coronavirus Disease 2019 (COVID-19), but the underlying mechanisms are still disputable. AIM: Herein we aimed to reveal a previously unrecognized mechanism that thymosin-α1 prevents COVID-19 by binding with angiotensin-converting enzyme (ACE), which was inspired from the tool of network pharmacology. METHODS: KEGG pathway enrichment of thymosin-α1 treating COVID-19 was analyzed by Database of Functional Annotation Bioinformatics Microarray Analysis, then core targets were validated by ligand binding kinetics assay and fluorometric detection of ACE and ACE2 enzymatic activity. The production of angiotensin I, angiotensin II, angiotensin (1-7) and angiotensin (1-9) were detected by enzyme linked immunosorbent assay. RESULTS: We found that thymosin-α1 impaired the expressions of angiotensin-converting enzyme 2 and angiotensin (1-7) of human lung epithelial cells in a dose-dependent way (p < 0.001). In contrast, thymosin-α1 had no impact on their ACE and angiotensin (1-9) expressions but significantly inhibited the enzymatic activity of ACE (p > 0.05). CONCLUSION: The bioinformatic findings of network pharmacology and the corresponding pharmacological validations have revealed that thymosin-α1 treatment could decrease ACE2 expression in human lung epithelial cells, which strengthens the potential clinical applications of thymosin-α1 to prevent severe acute respiratory syndrome coronavirus 2 infection.


Asunto(s)
Enzima Convertidora de Angiotensina 2 , Tratamiento Farmacológico de COVID-19 , Inhibidores de la Enzima Convertidora de Angiotensina/farmacología , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Humanos , SARS-CoV-2 , Timalfasina/farmacología
11.
Infect Control Hosp Epidemiol ; 43(7): 876-885, 2022 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1275836

RESUMEN

OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic has resulted in shortages of personal protective equipment (PPE), underscoring the urgent need for simple, efficient, and inexpensive methods to decontaminate masks and respirators exposed to severe acute respiratory coronavirus virus 2 (SARS-CoV-2). We hypothesized that methylene blue (MB) photochemical treatment, which has various clinical applications, could decontaminate PPE contaminated with coronavirus. DESIGN: The 2 arms of the study included (1) PPE inoculation with coronaviruses followed by MB with light (MBL) decontamination treatment and (2) PPE treatment with MBL for 5 cycles of decontamination to determine maintenance of PPE performance. METHODS: MBL treatment was used to inactivate coronaviruses on 3 N95 filtering facepiece respirator (FFR) and 2 medical mask models. We inoculated FFR and medical mask materials with 3 coronaviruses, including SARS-CoV-2, and we treated them with 10 µM MB and exposed them to 50,000 lux of white light or 12,500 lux of red light for 30 minutes. In parallel, integrity was assessed after 5 cycles of decontamination using multiple US and international test methods, and the process was compared with the FDA-authorized vaporized hydrogen peroxide plus ozone (VHP+O3) decontamination method. RESULTS: Overall, MBL robustly and consistently inactivated all 3 coronaviruses with 99.8% to >99.9% virus inactivation across all FFRs and medical masks tested. FFR and medical mask integrity was maintained after 5 cycles of MBL treatment, whereas 1 FFR model failed after 5 cycles of VHP+O3. CONCLUSIONS: MBL treatment decontaminated respirators and masks by inactivating 3 tested coronaviruses without compromising integrity through 5 cycles of decontamination. MBL decontamination is effective, is low cost, and does not require specialized equipment, making it applicable in low- to high-resource settings.


Asunto(s)
COVID-19 , Virosis , COVID-19/prevención & control , Descontaminación/métodos , Equipo Reutilizado , Humanos , Máscaras , Azul de Metileno/farmacología , Respiradores N95 , Equipo de Protección Personal , SARS-CoV-2
12.
One Earth ; 3(5): 574-589, 2020 Nov 20.
Artículo en Inglés | MEDLINE | ID: covidwho-1144885

RESUMEN

Air-filtering masks, also known as respirators, protect wearers from inhaling fine particulate matter (PM2.5) in polluted air, as well as airborne pathogens during a pandemic, such as the ongoing COVID-19 pandemic. Fibrous medium, used as the filtration layer, is the most essential component of an air-filtering mask. This article presents an overview of the development of fibrous media for air filtration. We first synthesize the literature on several key factors that affect the filtration performance of fibrous media. We then concentrate on two major techniques for fabricating fibrous media, namely, meltblown and electrospinning. In addition, we underscore the importance of electret filters by reviewing various methods for imparting electrostatic charge on fibrous media. Finally, this article concludes with a perspective on the emerging research opportunities amid the COVID-19 crisis.

13.
Molecules ; 26(1)2020 Dec 31.
Artículo en Inglés | MEDLINE | ID: covidwho-1006941

RESUMEN

December 2019 saw the emergence of the coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), which has spread across the globe. The high infectivity and ongoing mortality of SARS-CoV-2 emphasize the demand of drug discovery. Angiotensin-converting enzyme II (ACE2) is the functional receptor for SARS-CoV-2 entry into host cells. ACE2 exists as a membrane-bound protein on major viral target pulmonary epithelial cells, and its peptidase domain (PD) interacts SARS-CoV-2 spike protein with higher affinity. Therefore, targeting ACE2 is an important pharmacological intervention for a SARS-CoV-2 infection. In this review, we described the two-way switch role of ACE2 in the treatment of novel coronavirus pneumonia and underlying comorbidities, and discussed the potential effect of the ACE inhibitor and angiotensin receptor blocker on a hypertension patient with the SARS-CoV-2 infection. In addition, we analyzed the S-protein-binding site on ACE2 and suggested that blocking hot spot-31 and hot spot-353 on ACE2 could be a therapeutic strategy for preventing the spread of SARS-CoV-2. Besides, the recombinant ACE2 protein could be another potential treatment option for SARS-CoV-2 induced acute severe lung failure. This review could provide beneficial information for the development of anti-SARS-CoV-2 agents via targeting ACE2 and the clinical usage of renin-angiotensin system (RAS) drugs for novel coronavirus pneumonia treatment.


Asunto(s)
Enzima Convertidora de Angiotensina 2/metabolismo , Antivirales/farmacología , Antivirales/uso terapéutico , Tratamiento Farmacológico de COVID-19 , Neumonía/tratamiento farmacológico , Neumonía/metabolismo , SARS-CoV-2/efectos de los fármacos , Animales , COVID-19/metabolismo , COVID-19/virología , Humanos , Neumonía/virología
14.
Nano Lett ; 21(1): 651-657, 2021 01 13.
Artículo en Inglés | MEDLINE | ID: covidwho-962235

RESUMEN

The global COVID-19 pandemic has changed many aspects of daily lives. Wearing personal protective equipment, especially respirators (face masks), has become common for both the public and medical professionals, proving to be effective in preventing spread of the virus. Nevertheless, a detailed understanding of respirator filtration-layer internal structures and their physical configurations is lacking. Here, we report three-dimensional (3D) internal analysis of N95 filtration layers via X-ray tomography. Using deep learning methods, we uncover how the distribution and diameters of fibers within these layers directly affect contaminant particle filtration. The average porosity of the filter layers is found to be 89.1%. Contaminants are more efficiently captured by denser fiber regions, with fibers <1.8 µm in diameter being particularly effective, presumably because of the stronger electric field gradient on smaller diameter fibers. This study provides critical information for further development of N95-type respirators that combine high efficiency with good breathability.


Asunto(s)
COVID-19/prevención & control , Respiradores N95/virología , Pandemias , SARS-CoV-2/ultraestructura , Microbiología del Aire , COVID-19/transmisión , COVID-19/virología , Aprendizaje Profundo , Filtración/estadística & datos numéricos , Humanos , Imagenología Tridimensional , Microscopía Electrónica de Rastreo , Respiradores N95/normas , Respiradores N95/estadística & datos numéricos , Nanopartículas/ultraestructura , Pandemias/prevención & control , Tamaño de la Partícula , Polipropilenos , Porosidad , Textiles/virología , Tomografía por Rayos X
15.
ACS Nano ; 14(10): 14017-14025, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: covidwho-779933

RESUMEN

In March of 2020, the World Health Organization declared a pandemic of coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The pandemic led to a shortage of N95-grade filtering facepiece respirators (FFRs), especially surgical-grade N95 FFRs for protection of healthcare professionals against airborne transmission of SARS-CoV-2. We and others have previously reported promising decontamination methods that may be applied to the recycling and reuse of FFRs. In this study we tested disinfection of three viruses, including SARS-CoV-2, dried on a piece of meltblown fabric, the principal component responsible for filtering of fine particles in N95-level FFRs, under a range of temperatures (60-95 °C) at ambient or 100% relative humidity (RH) in conjunction with filtration efficiency testing. We found that heat treatments of 75 °C for 30 min or 85 °C for 20 min at 100% RH resulted in efficient decontamination from the fabric of SARS-CoV-2, human coronavirus NL63 (HCoV-NL63), and another enveloped RNA virus, chikungunya virus vaccine strain 181/25 (CHIKV-181/25), without lowering the meltblown fabric's filtration efficiency.


Asunto(s)
Desinfección/métodos , Calor , Humedad , Máscaras/virología , Textiles/virología , Betacoronavirus/patogenicidad , Máscaras/normas , Polipropilenos/química , SARS-CoV-2 , Textiles/normas
16.
Dig Endosc ; 32(6): 914-920, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: covidwho-767221

RESUMEN

AIMS: To investigate control measures for COVID-19 pandemic in GIE centers in China. METHODS: This is a retrospective multi-center research, including seven centers. Data collection was from 1 February to 31 March 2020 and the same period in 2019. RESULTS: There were a total of 28 COVID-19 definite cases in these hospitals. Six out of seven GIE centers were arranged to shut down on 1 February, with a mean number of shutdown days of 23.6 ± 5.3. The actual workloads were only 10.3%-62.9% compared to those last year. All centers had a preoperative COVID-19 screening process. Epidemiological questionnaire, temperature taking and QR-code of journey were conducted. Chest CT scan was conducted during the shutdown period and continued in five centers after return to work. Antibody and nucleic acid test were applied in one to three centers. All endoscopists had advanced PPE. Five centers used surgical mask and the rest used N95 mask. Six centers used goggles or face shield. Five centers selected isolation gowns and the rest selected protective suits. The change frequency of these PPE was 4 h. Sterilizing measures were improved in six centers. Five centers utilized ultraviolet and six centers strengthened natural ventilation. Four and six centers used peracetic acid during the period of shutdown and return to work, alone or matched with OPA or acidified water. CONCLUSIONS: Many effective control measures were conducted in GIE centers during the outbreak, including patients' volume limitation, preoperative COVID-19 screening, advanced PPE and disinfection methods.


Asunto(s)
COVID-19/prevención & control , Endoscopía Gastrointestinal , Control de Infecciones/normas , COVID-19/epidemiología , China/epidemiología , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias , Estudios Retrospectivos , SARS-CoV-2
17.
Nano Lett ; 20(10): 7744-7750, 2020 10 14.
Artículo en Inglés | MEDLINE | ID: covidwho-759562

RESUMEN

As coronavirus disease 2019 (COVID-19) continues to spread, a detailed understanding on the transmission mechanisms is of paramount importance. The disease transmits mainly through respiratory droplets and aerosol. Although models for the evaporation and trajectory of respiratory droplets have been developed, how the environment impacts the transmission of COVID-19 is still unclear. In this study, we investigate the propagation of respiratory droplets and aerosol particles generated by speech under a wide range of temperatures (0-40 °C) and relative humidity (0-92%) conditions. We show that droplets can travel three times farther in low-temperature and high-humidity environment, whereas the number of aerosol particles increases in high-temperature and low-humidity environments. The results also underscore the importance of proper ventilation, as droplets and aerosol spread significantly farther in airstreams. This study contributes to the understanding of the environmental impact on COVID-19 transmission.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/transmisión , Modelos Biológicos , Neumonía Viral/transmisión , Aerosoles , Microbiología del Aire , Movimientos del Aire , Betacoronavirus/patogenicidad , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Espiración , Gravitación , Humanos , Humedad , Nanopartículas , Pandemias , Tamaño de la Partícula , Neumonía Viral/epidemiología , Neumonía Viral/virología , SARS-CoV-2 , Temperatura
18.
PLoS One ; 15(7): e0234851, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-627997

RESUMEN

A lack of N95 Filtering Facepiece Respirators (FFRs) during the COVID-19 crisis has placed healthcare workers at risk. It is important for any N95 reuse strategy to determine the effects that proposed protocols would have on the physical functioning of the mask, as well as the practical aspects of implementation. Here we propose and implement a method of heating N95 respirators with moisture (85°C, 60-85% humidity). We test both mask filtration efficiency and fit to validate this process. Our tests focus on the 3M 1860, 3M 1870, and 3M 8210 Plus N95 models. After five cycles of the heating procedure, all three respirators pass both quantitative fit testing (score of >100) and show no degradation of mask filtration efficiency. We also test the Chen Heng V9501 KN95 and HKYQ N95 finding no degradation of mask filtration efficiency, however even for unheated masks these scored <50 for every fit test. The heating method presented here is scalable from individual masks to over a thousand a day with a single industrial convection oven, making this method practical for local application inside health-care facilities.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/epidemiología , Descontaminación/métodos , Equipo Reutilizado , Calefacción/métodos , Humedad , Máscaras/virología , Neumonía Viral/epidemiología , Dispositivos de Protección Respiratoria/virología , COVID-19 , Infecciones por Coronavirus/virología , Filtración/instrumentación , Humanos , Ensayo de Materiales/métodos , Exposición Profesional/prevención & control , Pandemias , Neumonía Viral/virología , SARS-CoV-2
19.
Nano Lett ; 20(7): 5544-5552, 2020 07 08.
Artículo en Inglés | MEDLINE | ID: covidwho-459118

RESUMEN

The COVID-19 pandemic is currently causing a severe disruption and shortage in the global supply chain of necessary personal protective equipment (e.g., N95 respirators). The U.S. CDC has recommended use of household cloth by the general public to make cloth face coverings as a method of source control. We evaluated the filtration properties of natural and synthetic materials using a modified procedure for N95 respirator approval. Common fabrics of cotton, polyester, nylon, and silk had filtration efficiency of 5-25%, polypropylene spunbond had filtration efficiency 6-10%, and paper-based products had filtration efficiency of 10-20%. An advantage of polypropylene spunbond is that it can be simply triboelectrically charged to enhance the filtration efficiency (from 6 to >10%) without any increase in pressure (stable overnight and in humid environments). Using the filtration quality factor, fabric microstructure, and charging ability, we are able to provide an assessment of suggested fabric materials for homemade facial coverings.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/prevención & control , Máscaras , Pandemias/prevención & control , Neumonía Viral/prevención & control , Textiles , Aerosoles , Microbiología del Aire , COVID-19 , Infecciones por Coronavirus/transmisión , Electricidad , Diseño de Equipo , Filtración , Humanos , Máscaras/provisión & distribución , Microscopía Electrónica de Rastreo , Nanoestructuras/química , Nanoestructuras/ultraestructura , Nanotecnología , Tamaño de la Partícula , Equipo de Protección Personal/provisión & distribución , Neumonía Viral/transmisión , SARS-CoV-2
20.
ACS Nano ; 14(5): 6348-6356, 2020 May 26.
Artículo en Inglés | MEDLINE | ID: covidwho-175663

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential for protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protective equipment in these urgent times. We investigated multiple commonly used disinfection schemes on media with particle filtration efficiency of 95%. Heating was recently found to inactivate the virus in solution within 5 min at 70 °C and is among the most scalable, user-friendly methods for viral disinfection. We found that heat (≤85 °C) under various humidities (≤100% relative humidity, RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. At 85 °C, 30% RH, we were able to perform 50 cycles of heat treatment without significant changes in the filtration efficiency. At low humidity or dry conditions, temperatures up to 100 °C were not found to alter the filtration efficiency significantly within 20 cycles of treatment. Ultraviolet (UV) irradiation was a secondary choice, which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can potentially impact the material strength and subsequent sealing of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach all may lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.


Asunto(s)
Desinfección/métodos , Máscaras/normas , Dispositivos de Protección Respiratoria/normas , Desinfección/normas , Calefacción/métodos , Textiles/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA